Vertiv Holdings Co. has introduced the Vertiv™ PowerNexus MV UPS, a medium-voltage power solution designed to help colocation, neocloud and hyperscale data center operators accelerate utility grid connections, improve site utilisation and address evolving power infrastructure requirements.
Announced on November 12, 2026, in Columbus, Ohio, the new system is designed for outdoor deployment at the point of connection. By moving critical power infrastructure outside the data hall, Vertiv aims to preserve valuable indoor space for revenue-generating computing equipment while maintaining power protection.
The platform combines medium-voltage uninterruptible power supply (UPS) technology, fault ride-through capabilities and AI power smoothing in a single outdoor-rated system. It delivers peak operating efficiency of up to 98.5% and is designed to work with long-duration energy storage systems. Vertiv is engaging with customers globally, with shipments expected to begin in mid-2027.
“Data centers are facing new infrastructure challenges, including grid queues that can delay deployment and revenue generation, indoor space constraints that limit compute density, and evolving grid requirements that can challenge traditional infrastructure and architectural approaches,” said Kyle Keeper, senior vice president of the power management business unit at Vertiv. “The Vertiv PowerNexus MV UPS is designed as a system-level response to those challenges, combining medium-voltage power protection, fault ride-through and AI power smoothing in an outdoor platform designed to operate with long-duration energy storage, helping operators to focus on deploying compute, not coordinating infrastructure.”
Key Capabilities of Vertiv PowerNexus MV UPS
The new system is designed to address several power infrastructure requirements associated with AI data centers.
- Critical load protection: Designed to integrate with long-duration battery systems, the solution provides Class 1 output voltage quality in accordance with IEC 62040-3, helping protect critical loads during grid disturbances and upstream faults.
- Improved indoor space utilisation: Its outdoor-rated skid architecture moves critical power infrastructure outside the data hall, allowing more indoor space to be allocated to computing equipment.
- Fault ride-through and AI power smoothing: The platform is designed to support grid stability during fault conditions and absorb rapid fluctuations in AI workloads before they affect the grid.
- Operating efficiency: Its line-interactive topology delivers up to 98.5% efficiency under peak conditions, potentially reducing energy consumption and operating costs.
- Reduced diesel generator dependence: When integrated with long-duration battery systems, the solution can support battery-backed operation for up to four hours, helping reduce reliance on diesel generators for extended backup.
- Simplified deployment: A single-vendor skid architecture brings together UPS, batteries and other powertrain components to reduce coordination complexity.
- System design and simulation: A Power Systems Computer Aided Design (PSCAD) model enables customers to simulate system behaviour, validate integration and evaluate power quality and grid interactions before deployment.
Customer Demonstrations Validate System Performance
Vertiv recently conducted proof-of-concept demonstrations with QTS, SoftBank and Rosendin at its Global Power R&D and Customer Experience Center in Bologna, Italy.
Testing under steady-state and dynamic operating conditions demonstrated stable performance across loads ranging from 0% to 100%. The demonstrations also validated Class 1 voltage accuracy during rapid load changes and the system’s ability to withstand significant voltage disturbances.
These included a 100% voltage sag lasting 150 milliseconds and a 25% overvoltage condition lasting five seconds.
“Vertiv PowerNexus MV UPS demonstrated the performance and flexibility needed to support demanding AI data center applications,” said Ryan Kuithe, senior vice president, facilities operations at QTS. “During proof-of-concept testing at Vertiv’s Global Power R&D and Customer Experience Center, we validated the system’s ability to maintain stable power through dynamic load changes and voltage disturbances.”
Vertiv Plans Dedicated Medium-Voltage Laboratory in Italy
Vertiv is also expanding its research, testing and customer demonstration capabilities with a dedicated Medium Voltage Laboratory at its Global Large Power R&D and Customer Experience Center in Bologna, Italy.
The facility is scheduled to become operational in 2027. It will support research and development, full-voltage validation, customer demonstrations, service training and system-level testing for medium-voltage power architectures.
Planned areas of work include medium-voltage UPS systems, medium-voltage-to-800 VDC architectures and battery energy storage technologies. The facility will allow customers worldwide to evaluate and validate power infrastructure designs for next-generation AI data centers.
“By enabling full-voltage research and development, testing, customer demonstrations, and system-level validation, the facility will help customers evaluate new architectures with greater confidence as they plan the power systems required for AI-scale data centers, including 800 VDC,” said Giovanni Zanei, vice president, large power conversion, Vertiv.
With the PowerNexus MV UPS and its planned laboratory investment, Vertiv is expanding its focus on medium-voltage power infrastructure as data center operators address increasing AI workloads, grid constraints and demand for more efficient use of facility space.